The Ideal Evomax 2 series represents a line of high-efficiency, wall-mounted condensing boilers designed for commercial and industrial applications. These boilers feature automatic controls and fan-assisted combustion, offering reliable heating solutions. The series includes models from 30 to 150kW output.
Overview of the Ideal Evomax 2 Boiler Series
The Ideal Evomax 2 boiler series is engineered for high performance and efficiency in commercial heating systems. These wall-mounted, fully automatic condensing boilers are available in a range of outputs, from 30kW to 150kW, catering to diverse heating requirements. The series is characterized by its robust cast aluminum heat exchanger, ensuring long-lasting operation. Each boiler features full sequence automatic spark ignition and fan-assisted combustion, contributing to its efficiency. The Evomax 2 can be installed either on the wall or within a floor-mounted frame, offering flexibility in installation. The series includes models designed for both natural gas and LPG, providing options for different fuel sources. Ideal’s Evomax 2 boilers are designed to be easily cascaded, allowing up to six units to be linked for outputs as high as 900kW, making them suitable for larger installations. These boilers are designed to meet various installation requirements, making them a versatile choice for commercial heating.
Installation Procedures
Proper installation of the Evomax 2 involves several key stages. These include initial preparations, secure mounting, and correct connection of water and gas supplies. Adhering to the provided manual is crucial.
Initial Steps Before Installation
Prior to commencing any physical installation of the Ideal Evomax 2 boiler, a thorough site assessment is paramount. This involves verifying the structural integrity of the chosen wall or floor area to ensure it can adequately support the boiler’s weight. Check the availability and suitability of gas and water connections, ensuring they meet the boiler’s specifications and comply with local regulations. It’s crucial to confirm the correct flue system is selected and positioned according to the manufacturer’s guidelines to guarantee safe and efficient operation. Furthermore, a review of the electrical supply is essential to match the boiler’s power requirements. It’s also important to have all necessary tools and safety equipment ready. Finally, carefully read through the entire installation manual provided by Ideal Heating, paying particular attention to safety precautions and specific instructions for your chosen model of the Evomax 2. This thorough preparation helps avoid problems during installation.
Wall Mounting and Floor Frame Installation
The Ideal Evomax 2 boiler offers flexible installation options, accommodating both wall mounting and floor frame setups. For wall mounting, ensure the wall is capable of bearing the boiler’s weight, using appropriate fixings and brackets as specified in the installation manual. Precisely measure and mark the fixing points, confirming they are level for proper boiler alignment. If opting for a floor frame installation, assemble the frame according to the provided instructions, making sure it is stable and secured to the floor. The boiler must be carefully lifted and positioned onto the frame or wall brackets ensuring all fixings are correctly aligned and tightened. The use of a suitable lifting device may be necessary due to the weight of the unit. Always double check the level and stability of the boiler in either configuration before proceeding with further connections. Follow the manufacturer’s instructions closely for your specific Evomax 2 model.
Connecting Water and Gas Headers
Connecting the water and gas headers to the Ideal Evomax 2 boiler requires careful attention to detail, ensuring leak-free and safe operation. The water headers should be connected using the correct size and type of piping, following the flow and return designations. Use appropriate sealing materials and tighten all connections to the manufacturer’s recommended torque. For gas connections, only a qualified gas engineer should perform the work. The gas header should be installed with the necessary isolation valves and a gas filter. Check for gas leaks with an appropriate gas leak detection fluid or electronic gas detector, never with a naked flame. Ensure the gas supply is of the correct type and pressure. It is important to use the approved pipework materials. Double-check all connections before commissioning the boiler. The Ideal Evomax 2 is designed to work with specific header configurations, and reference to the installation guide is vital.
Servicing and Maintenance
Regular servicing and maintenance are crucial for the optimal performance and longevity of the Ideal Evomax 2 boiler. This includes routine checks, cleaning, and addressing any potential issues promptly according to the manufacturer’s guidelines.
Routine Checks and Maintenance Tasks
Regular maintenance is essential for the efficient and safe operation of your Ideal Evomax 2 boiler. Routine checks should include inspecting the boiler for any signs of leaks or corrosion, ensuring all connections are secure, and verifying that the pressure is within the recommended range. It is also important to check the flue system for any blockages or damage, as a clear flue is crucial for proper ventilation and combustion. The condensate trap should be checked and cleaned to prevent blockages. Additionally, the gas supply should be inspected by a qualified professional, and the combustion settings should be checked and adjusted if necessary to ensure optimal performance. Regular cleaning of the heat exchanger can prevent buildup and maintain efficiency. These routine checks will help to keep the boiler in peak condition, reduce the risk of breakdowns, and extend its lifespan. Always follow the detailed instructions in the Ideal Evomax 2 installation and service manual for specific procedures and frequency of checks.
Troubleshooting Common Issues
When facing issues with your Ideal Evomax 2 boiler, it’s crucial to approach troubleshooting systematically. Common problems include the boiler not igniting, which could stem from a gas supply issue, ignition failure, or a fault in the control system. If the boiler is operating erratically, check for low water pressure or airlocks within the system. Unusual noises could indicate a problem with the pump or other internal components. Error codes displayed on the control panel provide valuable clues; consult the user manual for their meaning and suggested remedies. If the boiler is overheating, investigate the circulation and make sure the system’s safety features are functioning correctly. Before attempting any repairs, always ensure the boiler is switched off and the gas supply is isolated. If the issue persists, it’s best to contact a qualified technician, as improper handling can cause further damage or risks. Always refer to the Ideal Evomax 2 installation manual for detailed troubleshooting procedures.
Technical Specifications
The Ideal Evomax 2 series features models with outputs from 30 to 150kW, available in both natural gas and LPG variants. Key design features include a robust cast aluminum heat exchanger, ensuring high efficiency.
Available Models and Output Ranges
The Ideal Evomax 2 boiler series offers a variety of models to suit different heating requirements, ranging in output from 30kW to 150kW. Specifically, the series includes the Evomax 2 30, 40, 60, 80, 100, 120, and 150 models, each designed to provide efficient heating for various commercial and industrial applications. These models are available in both standard and ‘P’ variants, such as the Evomax 2 30P, 40P, 60P, 80P, 100P, and 120P. The ‘P’ designation typically refers to models with slightly different configurations or features, often related to propane compatibility. These models cater to diverse needs, ensuring that there’s a suitable Evomax 2 for most commercial heating systems. The extensive range allows for precise matching of boiler output to heating demand, optimizing system efficiency and reducing energy consumption. Whether for a small office or a large industrial facility, the Evomax 2 series provides reliable and scalable heating solutions.
Key Features and Design
The Ideal Evomax 2 boilers are characterized by their robust cast aluminum heat exchangers, which ensure efficient heat transfer and long-term durability. These boilers feature a fully automatic sequence for spark ignition and fan-assisted combustion, contributing to their high efficiency and reliable performance. They are designed as wall-mounted units, but can also be installed within a prefabricated floor-mounted frame, offering flexibility in installation. The Evomax 2 series supports cascading up to six boilers, making it suitable for a wide array of applications with diverse heating demands. The boilers are designed with a focus on ease of installation and servicing, incorporating user-friendly controls and accessibility for maintenance. With their condensing technology, the Evomax 2 boilers are highly efficient, contributing to reduced energy consumption and lower operating costs. The modular design allows for simple and effective system expansion as heating needs evolve.
Additional Resources
Comprehensive manuals, CAD drawings, and specification sheets are available for download from the Ideal Commercial Boilers website. Warranty and commissioning terms can also be accessed online, ensuring complete support for the Evomax 2 series.
Where to Find Manuals and CAD Drawings
Accessing the necessary documentation for the Ideal Evomax 2 boiler series is straightforward, with a variety of resources available online. The primary location for obtaining official manuals, including installation, servicing, and user guides, is the Ideal Commercial Boilers website. These documents are typically available in PDF format, allowing for easy download and reference. Additionally, CAD drawings for the Evomax 2 models can also be found on the same site, crucial for accurate planning and integration into building systems. These resources cover all models within the Evomax 2 range, including the 30, 40, 60, 80, 100, 120, and 150kW versions, as well as their respective ‘P’ variants. Furthermore, third-party websites specializing in HVAC documentation may also provide access to these materials. Always ensure that the documents you are using are the most recent versions to align with the latest specifications. By utilizing these resources, installers and service personnel can ensure that the Evomax 2 boiler is installed, operated, and maintained correctly.
Warranty and Commissioning Information
Understanding the warranty terms and commissioning procedures for the Ideal Evomax 2 is crucial for ensuring long-term performance and reliability. Detailed warranty information, including the duration and coverage, can be found on the Ideal Commercial Boilers website. It is important to register the boiler after installation to activate the warranty, and this process typically involves submitting specific documentation. The commissioning process, as outlined in the installation manual, must be carried out by a qualified engineer. This involves a series of checks to confirm proper operation, including gas and water connections, and the correct setup of the control system. Failure to commission the boiler correctly may invalidate the warranty. Ideal also provides specific commissioning terms and conditions that should be reviewed before installation begins. These documents are available for download on their website alongside warranty information. Ensure all steps are followed to maintain the warranty and ensure peak efficiency.